Maintenance 9. Troubleshooting
202 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
2500
Specified event condition for Wait is
beyond the maximum count.
The maximum number of event
conditions is 8. Review the
2501
Specified bit number in the Ctr
function was not initialized with a
Review the program.
The specified
bit number
2502
Task number is beyond the
maximum count to execute.
The available number of tasks that
can be executed simultaneously is 32
for normal tasks, and 16 for
background tasks. Review the
2503
Cannot execute Xqt when the
specified task number is already
Review the program.
The specified
task number
2504
manipulator is already executing a
Rebuild the project.
2505
Not enough data for Input
statement variable assignment.
Check the content of communication
data. Review the program.
2506
Specified variable for the Input
statement is beyond the maximum
For OP, only one variable can be
specified. For other devices, up to
32 variables can be specified.
2507
All counters are in use and cannot
initialize a new counter with
The available number of the counters
that can be set simultaneously is 16.
2508
OnErr failure. Failed to process
the OnErr statement.
Rebuild the project.
2509
OnErr failure. Failed to process
the OnErr statement.
Rebuild the project.
2510 Specified I/O label is not defined.
The specified I/O label is not
registered. Check the I/O label file.
2511
SyncUnlock statement is used
without executing a previous
SyncLock statement. Review the
Review the program.
Signal
number
2512
SyncLock statement was already
executed.
The SyncLock statement cannot be
executed for the second time in a
Signal
number
2513 Specified point label is not defined.
The specified point label is not
registered. Check the point file.
2514
Failed to obtain the motor on time of
Reboot the controller.
2515
Failed to configure the date or the
Check whether a date and time is set
2516
Failed to obtain the debug data or
to initialize.
Reboot the controller.
2517 Failed to convert into date or time.
Check the time set on the controller.
Reboot the controller.
2518
Larger number was specified for the
start point data than the end point
Specify a larger number for the end
point data than that for the start point
Start point End point
Invalid format syntax for FmtStr$.
2520 File name is too long.
Check whether the specified point file
name is correct. The maximum
string length of the file name is 32.