Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 219
No.
Message
Remedy
Note 1
Note 2
3233 NoFlip/Flip was specified.
Setting value for the wrist orientation
is not specified in Wrist statement.
Specify either NoFilip or Flip.
3234 Port number was not specified.
Port number that indicates the file or
communication port is not specified in
Read, ReadBin, Write, and WriteBin
statements.
Refer to SPEL+ Language Reference
Read Statement” and specify a
proper file number or port number.
3235
String type variable was not
specified.
String type variable is not specified in
the command that requires
specification of string type variable as
a parameter. Specify a valid string
type variable.
3236
RS-232C port number was not
specified.
RS-232C port number is not specified
in OpenCom, CloseCom, and
SetCom statements. Refer to
SPEL+ Language Reference
OpenCom Statement” and specify a
proper port number.
3237
Network communication port
number was not specified.
Network communication port number
is not specified in OpenNet,
CloseNet, SetNet, and WaitNet
statement. Specify an integer from
201 to 216.
3238
Communication speed was not
specified.
Communication speed (baud rate) is
not specified in SetCom statement.
Refer to SPEL+ Language Reference
“SetCom Statement” and specify a
proper baud rate.
3239 Data bit number was not specified.
Data bit length is not specified in
SetCom statement. Refer to SPEL+
Language Reference “SetCom
Statement” and specify a proper data
bit length.
3240 Stop bit number was not specified.
Stop bit length is not specified in
SetCom statement. Refer to SPEL+
Language Reference “SetCom
Statement” and specify a proper stop
bit length.
3241 Parity was not specified.
Parity is not specified in SetCom
statement. Refer to SPEL+
Language Reference “SetCom
Statement” and specify a proper
parity.
3242 Terminator was not specified.
Terminator (end of send/receive line)
is not specified in SetCom and
SetNet statements. Refer to SPEL+
Language Reference “SetCom
Statement” and specify a proper
terminator.
3243 Hardware flow was not specified.
Hardware flow is not specified in
SetCom statement. Refer to SPEL+
Language Reference “SetCom
Statement” and specify a proper flow
control.