Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 227
No.
Message
Remedy
Note 1
Note 2
3409 Point list is not specified.
Pixel coordinate or robot coordinate is
not specified as a continuous point
data in VxCalib statement. Specify
a continuous point data in the
following format: P (start : end)
3410 Code type is not specified.
CodeType property setting value is
not specified in VSet statement.
Refer to Vision Guide 7.0 Properties
& Results ReferenceCodeType
Property” and specify a proper setting
value.
3411 Edge type is not specified.
EdgeType property setting value is
not specified in VSet statement.
Refer to Vision Guide 7.0 Properties
& Results Reference EdgeType
Property” and specify a proper setting
value.
3412 ECC type is not specified.
ErrorCorrection property setting value
is not specified in VSet statement.
This error is for the old RC+6.x.
Setting of the old version is possible
by compiler version setting. Refer to
Vision Guide 6.0 Properties & Results
Reference ErrorCorrection Property
and specify a proper setting value.
3413 ImageColor type is not specified.
ImageColor property setting value is
not specified in VSet statement.
Refer to Vision Guide 7.0 Properties
& Results Reference “ImageColor
Property” and specify a proper setting
value.
3414 Point type is not specified.
PointType property setting value is
not specified in VSet statement.
Refer to Vision Guide 7.0 Properties
& Results ReferencePointType
Property” and specify a proper setting
value.
3415 Reference type is not specified.
ReferenceType property setting value
is not specified in VSet statement.
Refer to Vision Guide 7.0 Properties
& Results ReferenceReferenceType
Property” and specify a proper setting
value.
3416 Edge type is not specified.
Logic (edge type) of the trigger input
is not specified in SetLatch
statement. Specify either 0
(negative logic) or 1 (positive logic).
3417 Port number is not specified.
R-I/O input port number where the
trigger input is connected is not
specified in SetLatch statement.
Refer to SPEL+ Language Reference
SetLatch Statement” and specify a
proper port number.