Maintenance 9. Troubleshooting
234 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
3808
Specified syntax cannot be used in
the current version.
LJM and PerformMode parameters of
motion commands may not be
specified depending on the compiler
version.
LJM parameter: 6.0.x.x or later
PerformMode parameter: 7.0.4.x or
later
Check the compiler version from the
project property.
3809
Module variables cannot be used in
the command window.
Module variable cannot be accessed
from the command window. Check
the input command.
3812
Specified function cannot be used
with a Remote User Output.
Functions for condition expression of
the user defined remote output are
limited. Refer to EPSON RC+7.0
User’s Guide11.8 User-defined
Remote Output I/O” and specify a
valid function.
3813
User defined label, function and
variable cannot be used with a
Remote User Output.
User defined label, function and
variable cannot be used with
condition expression of the
user-defined remote output. Correct
the condition expression.
3814
Object code size is beyond the
available size.
A combination of multiple statements
is exceeding the available size of the
intermediate code which can be
executed at once (1024 bytes).
Divide the statements.
3815
Parameter cannot be specified for
property or status in the command
window.
Delete the parameter and execute
again.
When executing FGet or MPGet
statement from a command window,
a parameter cannot be specified to a
property or status.
Delete the parameter and execute
again.
3850
File not found.
-
3851 Point file not found.
Failed to read the point file which
configures the project. Check the
project folder if the file exists.
3852 I/O label file not found.
Failed to read the I/O label file which
configures the project. Check the
project folder if the file exists.
3853 User error label file not found.
Failed to read the user error label file
which configures the project. Check
the project folder if the file exists.
3854
Force file does not exist.
Check the project folder if the file
exists.
Failed to read the force file which
configures the project. Check the
project folder if the file exists.
3860
I/O label file not supported format.
Regenerate the I/O label file.
3861
User error label file has
unsupported file format.
Regenerate the user error file.
3862
Point file has unsupported file
format.
Regenerate the point file.
3863
Vision project file has unsupported
file format.
Regenerate the vision sequence.
3864
GUI Builder project file has
unsupported file format.
Regenerate the GUI Builder form.
3865
OBJ file not supported format.
Rebuild the project.

Table of Contents