Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 255
5041
Motor torque output failure in low
power state. Check the power
cable connection, robot, brake,
driver, or motor.
Check the robot. (Smoothness,
backlash, non-smooth motion,
loose belt tension, brake)
Check the interference with the
peripheral equipment. (Collision,
contact)
Check the model setting.
Check the power cable
connection.
Check the robot power wiring.
(Missing pin, disconnection,
short-circuit)
Check the power supply voltage.
(Low power supply voltage)
Replace the motor driver.
Replace the DMB.
Replace the motor.
For T series, replace the CPU
board and motor unit in addition
5042
Position error overflow in high
power state. Check the power
cable connection, the robot, the
driver and the motor.
Specify the Weight/Inertia setting.
Check the load.
Check the robot. (Smoothness,
backlash, non-smooth motion,
loose belt tension, brake)
Check the interference with the
peripheral equipment. (Collision,
contact)
Check the model setting.
Check the power cable
connection.
Check the robot power wiring.
(Missing pin, disconnection,
short-circuit)
Check the power supply voltage.
(Low power supply voltage)
Replace the motor driver.
Replace the DMB.
Replace the motor.
For T series, replace the CPU
board and motor unit in addition