EPSON Stylus C110/C120/D120 Revision B
TROUBLESHOOTING Troubleshooting 49
• Power on
• Anywhere
When turning on the power, the Carriage
Unit collides to the Change Lever located
to the front side of the printer.
PF Motor
1. Check if the PF Motor Connector Cable is connected to
CN9 on the Main Board.
1. Connect the PF Motor Connector Cable to CN9
on the Main Board.
2. Check if the PF Motor Connector Cable is not damaged. 2. Replace the PF Motor with a new one.
3. Check if the PF Motor operates. 3. Replace the PF Motor with a new one.
ASF Unit
1. Check if the Compression Spring 2.36 does not come off
in the Change Lever.
1. Replace the ASF Unit with a new one.
The Carriage Unit collides with the Upper
Paper Guide Unit when power is turned
on.
Upper Paper Guide
Unit
1. Check if the Paper Guide Upper Unit is correctly
assembled.
1. Reassemble the Upper Paper Guide Unit to the
Main Frame correctly.
Table 3-3. Check point for fatal error according to each phenomenon
Occurrence timing
CR position
Detailed phenomenon
Defective unit/
part name
Check point Remedy