Epson Stylus Pro 3800/3800C/3850/3880/3885/3890 Revision C
DISASSEMBLY & ASSEMBLY Disassembly/Assembly Procedure (Group 1) 98
4.3.3.3 HOUSING, FRONT, LEFT
1. Open the STACKER, C.
2. Remove the screw that secures the HOUSING, FRONT, LEFT to the main unit.
One C.B.P. 3 x 8 screw (6 ± 1 kgf.cm)
3. Pull the upper part of the HOUSING, FRONT, LEFT toward you to release the
upper rib and the two lower hooks, and remove the HOUSING, FRONT, LEFT.
Figure 4-9. Removing the HOUSING, FRONT, LEFT
Be sure to engage the two lower hooks with the cutouts, and align
the positioning socket with the rib on the main unit.
rib
hooks
C.B.P. 3x8
HOUSING, FRONT, LEFT
STACKER, C