4.3.6.5 APG SENSOR
1.
Remove the HOUSING, UPPER.
(p107)
2. Remove the COVER, CR. (p152)
3. Remove the screw that secures the MOUNT PLATE, DETECTOR, PG, and
remove the MOUNT PLATE, DETECTOR, PG.
One C.B.P. 3 x 8 screw (5 ± 1 kgf.cm)
4. Disengage the four tabs that secure the APG SENSOR to the MOUNT PLATE,
DETECTOR, PG, and remove the APG SENSOR.
5. Disconnect the connector from the APG SENSOR.
Figure 4-53. Removing the APG SENSOR
When installing the MOUNT PLATE, DETECTOR, PG to the
CARRIAGE, ASSY., be sure to insert the positioning holes of the
MOUNT PLATE, DETECTOR, PG over the guide pins of the
CARRIAGE, ASSY. See Figure 4-53.
C.B.P. 3x8
MOUNT PLATE, DETECTOR, PG
tabs
positioning points
APG SENSOR
connector