2. Installation
Safety and Installation (T, VT / EPSON RC+ 7.0) Rev.15 69
AC power line:
Install an earth leakage circuit breaker or a circuit breaker.
For the rated electric current of the circuit breaker, refer to the following set values.
Manipulator
Power
Rated electric current
T3 series
AC100V
10A
AC200V
5A
T6 series
VT
series (AC specification)
AC100V
20A
AC200V
10A
DC power line:
Install a circuit protector.
For the rated electric current of the circuit protector, refer to the following set values.
Manipulator
Power
Rated electric current
VT
series (DC specification)
DC48V
40A
If you install a circuit protector, please select one that will handle the above
mentioned “peak current”.
The power receptacle shall be installed near the equipment and shall be easily
accessible.