ET 201i DC
INSTALLATION 0-5452
3-10
3.09 LIFT TIG (GTAW) Setup
Set Process Selectio
n
Switch to LIFT TIG.
Positive Output
Terminal
(Dinse™ 50)
Negative
Output
Terminal
(Dinse™ 50)
Art # A-09785_AB
Set Welding Current
as specified by the
Electrode Manufacturer.
Secure the gas cylinder in an
upright position by chaining it
to a stationar
y support to prevent
falling or tipping.
Switch to 2T/4T
Set DOWN Slope
Figure 3-6: Setup for LIFT TIG (GTAW) Welding