EasyManua.ls Logo

ESAB ET 201i DC - Section 5: Service; Maintenance and Inspection

ESAB ET 201i DC
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ET 201i DC
0-5452 SERVICE
5-1
5.01 Maintenance and Inspection
The only routine maintenance required for the power
supply is a thorough cleaning and inspection, with the
frequency depending on the usage and the operating
environment.
WARNING
There are extremely dangerous voltages and power
levels present inside this product. Disconnect
primary power at the source before opening the
enclosure. Wait at least two minutes before open-
ing the enclosure to allow the primary capacitors to
discharge.
To clean the unit, open the enclosure and use a vacuum
cleaner to remove any accumulated dirt and dust. The unit
should also be wiped clean, if necessary; with solvents
that are recommended for cleaning electrical apparatus.
!
CAUTION
Do not blow air into the power supply during
cleaning. Blowing air into the unit can cause metal
particles to interfere with sensitive electrical
components and cause damage to the unit.
SECTION 5:
SERVICE
Warning!
Disconnect input power before maintaining.
Each Use
Visual check of
regulator and pressure
Visual check of torch
Consumable parts
W eek ly
Visually inspect
the torch body
and consumables
Visually inspect the
cables and leads.
Replace as needed
3 Months
Clean
exterior
of power supply
6 Months
Replace all
broken parts
Bring the unit to an authorized
ESAB Service Center
to remove any accumulated dirt
and dust from the interior.
This may need to be done more
frequently under exceptionally
dirty conditions.
Maintain more often
if used under severe
conditions
Art # A-13036