EasyManua.ls Logo

ESAB ET 201i DC - HF TIG (GTAW) Setup

ESAB ET 201i DC
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ET 201i DC
INSTALLATION 0-5452
3-12
3.10 HF TIG (GTAW) Setup
Set Process Selection
Switch to LIFT TIG or HF TIG.
Positive Output
Terminal
(Dinse™ 50)
Negative
Output
Terminal
(Dinse™ 50)
Art # A-10100_AB
Set Welding Current
as specified by the
Electrode Manufacturer.
Secure the gas cylinder in an
upright position by chaining it
to a stationar
y support to prevent
falling or tipping.
Switch to 2T/4T
Set DOWN Slope
Figure 3-7: Setup for HF TIG (GTAW) Welding of ET 201i DC