-- 6 4 --
fzb2d4ea
14.3 Changing the program in the PEH electronics:
S Store trimming data in the welding power source
(see “Trimming data to the welding power source” on page 63).
S Replace the flash memory (IC15) on the NME card (AP2).
S Recall trimming data from the welding power source
(see “Trimming data back to the PEH electron ics” on page 63).
14.4 Changing programs in the PEH electronics and the welding
power source:
S Store trimming data in the welding power source
(see “Trimming data to the welding power source” on page 63).
S Replace the flash memory (IC15) on the NME card (AP2).
S Recall trimming data from the welding power source
(see “Trimming data back to the PEH electron ics” on page 63).
The right trimming data for the PEH electronics are now available in the new
electronics program.
S Replace the flash memory (IC6) in the welding power source.
S Switch on the welding power source.
In the event error code 111.01 should come up, the power source must be
switched off and then on again for correct initiation.
GB