ETS Series AC Servo User's Manual
3.2.2 I/O Signal Connector (CN1_A/CN1_B/CN1_C) Terminal Layout
0:/COIN(/VCMP)
1:/TGON
2:/S-RDY
3:/CLT
4:/BK
5:PGC
6:OT
7:/RD
8:/HOME
9:/TCR
0:Positioning completion (speed agree detection)
1:Running signal output
2:Servo ready
3:Torque limit output
4:Brake interlock output
5:C pulse output
6:Over travel signal output
7:Servo enabled motor excitation output
8:Home completion output
9: Torque detection output
Servo alarm:Turns off when an error is detected.
Control power supply input for I/O signals:
Provide the +24V DC power supply
0:/S-ON
1:/P-CON
2:P-OT
3:N-OT
4:/ALM-RST
5:/CLR
6:/PCL
7:/NCL
8:/G-SEL
9:/JDPOS-JOG+
A:/JDPOS-JOG-
B:/JDPOS-HALT
C:Reserved
D:SHOME
E:ORG(ZPS)
0:Servo ON
1:P/PI control input
2:Forward run prohibited
3:Reverse run prohibited
4:Alarm reset
5:Position error pulseclear input
6:Forward torque limitinput
7:Reverse torque limitinput
8:External switch gain switching
9:Position control (contact reference)-forward direction
JOG
A:Position control (contact reference)-reverse direction
JOG
B:Position control (contact reference)-stop JOG
C:Reserved
D:Hometrigger
E:Zero position
Power supply input for open collector reference