ETS Series AC Servo User's Manual
- 91 -
Codes Display
Code
Meaning
Baseblock
Servo OFF(servomotor power OFF)
Run
Servo ONservomotor power ON
Forward Run Prohibited
CN1_A/B/C_12P-OTis OFF.
Reverse Run Prohibited
CN1_A/B/C_13N-OTis OFF.
Alarm Status
Displays the alarm number.
Press ENTER key to clear the present servo alarm.
5.1.5 Operation in Parameter Setting Mode
The servo drive offers a large number of functions, which can be selected or adjusted by the parameter settings. Refer
toA.1 Parameter List for details.
Parameter Setting Procedures
The parameter settings can be used for changing parameter data. Before changing the data, check the permitted range of
the parameter.
The example below shows how to change parameter Pn102 from “100” to “85”.
1 Press MODE key to select the parameter setting mode.
2 Press INC key or DEC key to select parameter number.
3 Press ENTER key to display the current data of Pn102.
4 Press the INC or DEC key to change the data to the desired number 00085. Hold the key to accelerate the changing
of value. When the maximum value or minimum value is reached, pressing INC or DEC key respectively, will have no
effect.
5 Press the ENTER or MODE key once to return to the display of Pn102.