4.1.5. Power supply requirements
DANGER: Connecting Iqon to the power supply other than as specified in this section can result
in incompatibility of the installation as well as the risk of electric shock, and thus cause damage to Iqon,
and injury or death.
• Only connect Iqon to a power supply in a configuration that is specified in this section.
Earthing
system
TN-system PE-cable
TT-system
Earth electrode installed separately (self-
installed)
Power input
(phase)
3-phase 400 V ± 10% 50/60 Hz
MCB
(Miniature
Circuit
Breaker)
The power supply MCB must match the power rating of the charging station.
Power supply wiring
The table below shows how to connect the power supply to Iqon, depending on the specifications of
the power supply cabinet and the version of Iqon.
EN
4. Installation instructions
20