7700FR/7800FR MultiFrame
7800TR-32x24 Modular Tally Router
Revision 1.2 Page - 9
The card edge serial port is used for configuration, debug, and for upgrading the firmware on the card.
Press ENTER in the terminal program and a “CLI>” prompt will be displayed. It is not recommended to
play around with the command line interface unless under direction of Evertz customer support. The
following commands may be used to configure, upgrade, or find information about the unit:
Will display hardware and software version of the tally router
Used to configure the TCP/IP settings for the Ethernet port. Enter on one line:
ifconfig 0 inet [IP] netmask [SUBNETMASK] broadcast [BROADCAST]
gateway [GATEWAY]
Will reboot the unit (in order to perform a serial software upgrade)
Table 3-4: Command Line Interface Commands
3.3.3 Frame Status LEDs
These two LEDs indicate the overall health of the card. During normal operation the Green LED will be
on, and the Red LED will be off. If the Green LED is off or the Red LED is on, this indicates a problem
with the card. This fault condition can trigger the global frame status if jumper J15 is placed in the
FAULT position. This will cause the Frame Status LEDs on the power supply of the frame to turn Red,
and will also cause the GROC connection on the back of the frame to go into the fault position. A
triggered frame status can also be detected by the frame controller, if one is installed in the frame.
3.3.4 LED Display
The dot matrix LED display is used to display the product name (7800TR-32x24), and also the current
firmware version and build, as well as the currently configured IP address. These three pieces of
information will scroll alternately across the display.