26
TROUBLESHOOTING
FURTHER ADVICE
Should the EazyPod Automatic not function as set out in this manual,
more fault finding information can be found on our website:
www.evolutionaqua.com
There is no power to the control box
- Check the wiring is correctly installed. Seek advice from a suitably
qualified electrician if in doubt.
- Check the mains connection to the control box. Seek advice from a
suitably qualified electrician if in doubt.
- Check the fuse inside the control box. This is located in the hinged
compartment on the left hand side of the pump connector block. The
fuse is a standard 10 Amp glass fuse.
- Please be aware that every control box system is fully factory tested.
EazyPod Automatic does not drain to waste
- Check that the 1½” ball valve on the EazyPod Automatic is in an open
position.
(You can check this by removing the union end from the waste valve)
- Is cleaning cycle fully operational. From initiating a cleaning cycle it
will take 3 to 4 minutes before the automated waste valve opens.
- Check automated waste valve is connected correctly. Please be aware
that every waste valve is fully factory tested.
EazyPod Automatic does not close waste valve
- You will find out that the circulation pump will not switch on and the
green and amber light are both illuminated.
- Remove the unions from the waste valve and check for any blockages.
- Check the fuse inside the control box. This is located in the hinged
compartment on the left hand side of the pump connector block. The
fuse is a standard 10 Amp glass fuse.
- If this does not solve the problem, contact your Evolution Aqua dealer.
LOCATION OF FUSES