04012XXX
EXCELL PRECISION CO., LTD
ZSME400000011
54
Input signal configuration
Press the key
Input desired
Parameter code
Press the key
Display shows the existing
parameter code. Input
new code as required.
Press the key
Continue to another function setting
or press key to escape
Item
Function
Setting value
Default
Parameter Description
IN - 01
Input 1
0 None
1 Zero
2 Tare
3 Tare reset
4 Start batching
5 Stop batching
6 Discharge Command
7 Hold
8 Hold display & I/O reset
9 Totalise (Accu) Command
10 Clear totaliser (Accu)
11 Clear previous total (Accu) Value
12 Start to compare
13 Serial and parallel printer manual output
14 Net / Gross
1
IN - 02
Input 2
2
IN - 03
Input 3
3
IN - 04
Input 4
4
IN - 05
Input 5
5
IN - 06
Input 6
6
IN - 07
Input 7
7
IN - 08
Input 8
8
Increment flashing digit
Decrement flashing digit
Move flashing point left
Move flashing point right
Store data in memory
Exit / Escape