EXCELL PRECISION CO., LTD.
0201810X ZSME300000292
20
Animal Scale Hold Setup (hold 4)
3-6 F11 ID Code Setting
(must be used with r n P 1, r n P 2, r n P 8 of F5)
Press key or key to select F11
hold 0 = No hold function
hold 1 = For varying weighing value, the scale will automatically hold the maximum weighing value to
display. To exit hold mode, press any key (except the key).
hold 2 = After the scale is stabilized, the scale will automatically hold the display value( not changeable
due to external variables)To exit hold mode, press any key.( except the key )
hold 3 = After the scale is stabilized, the scale will automatically hold the display value( not changeable
due to external variables).After zero return ( or weight is less than 10d), the scale exits the
hold mode automatically.
hold 4 = Animal Scale function. When animal is on the scale platter and is stable, the scale will
automatically hold the display value (not changeable due to external variables). After the
animal is off the scale platter, the scale exits the hold mode automatically.
Error Allowance Range setup:
Use and to enter value ranged
from 1%~100%.Default is 10%.
Numbers of count to average:
Use and to select one of 1, 2, 4, 8,
16, 32, 64. Default is 8.
Select hold 4
Press key
Press key
Press key
Press key
%
Machine ID code setting:
Use and to set 01 ~ 99. Default setting: 00
(1) “00”: RS-232 does not transmit Machine ID.
(2) “01~99”: RS-232 transmits Machine ID.
Press key