Press key 2 times the display shows .
Press key 4 times the display shows .
Preset “High limit” ( High limit Low limit ) e.g. High limit = 25 kg
Press key 1 time the display shows .
Press key 1 time the display shows .
Press key 2 times the display shows .
Press key 1 time the display shows .
Press key 5 times the display shows .
Press key 3 times the display shows .
Preset “Beeper value” ( Refer to Note ) e.g. Beeper value = 22
Press key 1 time the display shows
Press key 2 times the display shows
Press key 1 time the display shows
Press key 2 times the display shows
Press key 1 times the display shows .
Preset Single point (preset low limit only):
After “preset low limit” procedures is completed and the display shows .
, then press key again, the display shows . . This means that the
“preset single point” procedure is completed.
NOTE
_ _ _ x x
A B
A Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
3 = open warning device: when the weight is higher than HI value and the
weight is stable, LCD is on and Relay Card open.
B Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.),
the beeper beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the

Questions and Answers: