WEEKLY COMBUSTION CHAMBER AND THE
ASH TRAY:
It is recommended to remove the ash in the combustion chamber
at least once a week using a suitable vacuum cleaner.
To facilitate cleaning, we recommend the activation of the "CLEAN
COMBUSTION CHAMBER" See chapter
a
OTHER FUNCTIONS.
Weekly or when necessary:
• empty the ashes from the drawer.
• clean the holes inside the door.
DAILY SCRAPERS:
HP1522: The heat exchangers must only be cleaned when the
generator is cold! Cleaning the heat exchangers allows to ensure
constant heat output over time. This type of maintenance must
be performed at least once a day. To do this, just use the relevant
scrapers positioned in the upper part of the generator, making
the
upward movements and vice versa several times.
HP30: The cleaning of the heat exchangers is carried out
automatically using a mechanical system that allows to guarantee
over time constant heat output.
J
A CLEAN BRAZIER ENSURES SUCCESSFUL OPERATION!
KEEPING THE BRAZIER AND ITS HOLES ALWAYS THOROUGHLY CLEAN
FROM ANY RESIDUE FROM THE COMBUSTION, GUARANTEES EXCELLENT
COMBUSTION OF THE GENERATOR OVER TIME, TO AVOID ANY MALFUNCTIONS
THAT MAY REQUIRE THE INTERVENTION OF THE TECHNICIAN.
IT IS POSSIBLE TO USE THE FUNCTION IN THE USER MENU
"ADJUSTMENT SET PELLET LOAD TO ADJUST COMBUSTION BASED
ON THE DESCRIBED REQUIREMENTS.
BURN POT
HOLES
25