ALARMS
Message
Display D1
Cause Solution
Indicates the presence of an alarm
This indicator lights up when one of the alarms described
below is in progress and is accompanied by the corresponding
indication on display D1. To reset the alarm, press button 1
and hold for three seconds when the stove is completely cold.
If the light is flashing, it indicates that the depression sensor is
deactivated.
All resetting operations must be carried out by an
authorised technician
GAS FAIL
The flue gas motor is blocked
The speed control probe is faulty.
No power supply to the flue gas
motor.
All resetting operations must be carried out by an
authorised technician
GAS PROBE KO
flue gas probe is broken.
flue gas probe is
disconnected from the board.
All resetting operations must be carried out by an
authorised technician
HIGH GAS TEMP
-flow fan is faulty.
Excessive pellet feed.
No power supply to the cross-flow fan.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
).
Other resetting operations must be carried out by an
authorised technician.
DEPRESSION KO
The flue gas exhaust pipe is
The combustion chamber is dirty.
The pressure sensor is faulty.
The ash drawer is not closed properly.
door is not closed properly.
Check to make sure that the exhaust outlet and the
combustion chamber are clean.
Check to see if the drawer is sealed properly.
Check to see if the door is sealed properly.
Other resetting operations must be carried out by an
authorised technician.
IGNITION FAIL
The pellet tank is empty.
The spark plug is faulty or out of
position.
Inadequate pellet load setting.
Check the level in the pellet tank.
Check the procedures described in “
Ignition”
.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
)
Other resetting operations must be carried out by an
authorised technician.
IGNITION FAIL
BLACK OUT
No electricity during the lighting
phase.
Press button 1 to switch off the stove and repeat the
procedure described in “
Ignition
”.
NO PELLET
The pellet tank is empty.
Pellet feeding is insufficient.
The feed motor still has to settle in.
The geared motor is not loading
pellets.
Check the level in the pellet tank.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
).
Other resett
ing operations must be carried out by an
authorised technician.
HIGH WATER TEMP
The circulation pump is blocked.
Insufficient system pressure.
Presence of air in the system.
Check the pressure of the water system.
Bleed the air from the system.
Other resetting operations must be carried out by an
authorised technician.
DOOR BLOCKED
Automatic brazier cleaning is blocked.
All resetting operations must be carried out by an
authorised technician.
COOLING WAIT
+ ALARM
Attempt to release alarm with stove
still cooling
Every time the stove visualises one of the above-listed alarms
it will automatically switch off.
The stove will block any attempt to release the alarm during
this phase visualising the alarm itself and ATTE alternately .
Release of the alarm using button 1 is only possible when the
appliance is switched off.
TELEPHONE
- - - - - - - - - -
Display of the service centre telephone
When an alarm occurs, the type of alarm detected and the
telephone number of the service centre flash on the dis
If the number has not been entered, the display shows a