40
Chapter 12
USER PARAMETERS
Summary table
Display D1 Display D2 Function
06:00 B Start day phase/end night phase
22:00 C Start night phase/end day phase
25°C D Day phase max. temperature
20°C E Night phase max. temperature
Once this function is active, it is still necessary to light the stove using button 1. When the stove switches o
because the maximum temperature has been reached, the message “DOFF” appears on D1.The stove will
switch on again automatically when the room temperature is 3°C lower than the maximum temperature
set.
Es. Status of the stove – DOFF
Max. temperature set - 25°C
When the room temperature goes below 22°C (25 – 3 = 22°C), the stove will automatically start again.
This only occurs if the stove is in “DOFF” status, not in “OFF” status.
Manual controls via the front panel or remote control take precedence over any programmed settingse.
PELLET FEED ADJUSTMENT
If the stove has operating problems due to the quantity of pellets, you can adjust the pellet feed directly
from the remote control.
Problems related to the quantity of pellets fall into one of two categories:
LACK OF PELLETS:
The stove cannot develop a suitable ame, tending to burn very poorly even at high speeds.
At the lowest speed, the stove tends to almost burn out, causing the stove to go into “ NO PELL” alarm
status.
When “ NO PELL” is displayed, there may still be some unburned pellets in the burn pot.
EXCESS PELLETS:
The stove develops a very high ame even at low speeds.
The ame tends to soil the stove window, darkening it almost completely.
The burn pot tends to get incrusted, blocking the air intake holes, due to the excessive pellet load that
is only partially burned.
If this problem occurs just a few months after installation, check to make sure that the
user is correctly carrying out the regular cleaning schedule described in the instruction
manual.