51
TABLE OF DISPLAY MESSAGES
Chapter 14
TABLE OF DISPLAY MESSAGES
INDICATIONS
Message
Cause Solution
Display
ATTE
An attempt is made to switch on a stove again
when it has just been shut down (normal
shutdown or caused by an alarm situation).
When the stove has just been shut down (normal
shutdown or caused by an alarm situation), you
have to wait until it is completely cold and then
clean the burn pot.
It is possible to re-start the stove only after having
carried out this operation.
HOT
Room thermostat set at maximum value.
In this operating mode the stove no longer has a
temperature level but is working manually with all
5 power levels. To exit this function, simply lower
the room temperature by pressing button 2.
LOU
Room thermostat set at minimum value.
In this operating mode, the stove works only at
the 1st power level no matter what power is set.
To exit this function, simply raise the room
temperature by pressing button 3.
T ON
An external thermostat has been connected.
The room thermostat probe is disconnected.
The room thermostat probe is interrupted.
To exclude an external thermostat, just disconnect
it.
Other resetting operations must be carried out by
an authorised technician.
STBY
The stove is o and on standby to be re-started.
In this mode, the stove can be switched on/o
by means of a supplementary thermostat (see
“Mechanical thermostat with energy saving”).
To exclude this function, simply raise the room
temperature by pressing button 3.
DOFF
The stove is o due to the “Day/Night Temperature
Function” and on standby to be re-started.
To stop the stove from starting again due to the
“Day/Night Temperature Function”, press button 1
and hold for three seconds, which switches the
stove OFF.
To disenable this function completely, press
button 4 and hold it down, then press button 5.
RAF / BLAC OUT
No power.
When the shutdown cycle is completed, the stove
will light again automatically.
PUL
The automatic cleaning of the burn pot is in
progress.
The automatic cleaning of the burn pot takes place
at regular intervals of continuous operation.
The automatic cleaning is not carried out when
the stove is in power level 1 position.