Chapter 14
TABLE OF DISPLAY MESSAGES
ALARMS
Message
Cause Solution
Display
Indicates the presence of an alarm.
This indicator lights up when one of the alarms described
below is in progress and is accompanied by the corresponding
indication on display D1. To reset the alarm, press button 1 and
hold for three seconds when the stove is completely cold.
FUM FAIL
Breakdown correlated to the fumes
exhaust motor.
All restore operations must be carried out by an authorised
technician.
FUMI TC
Breakdown correlated to the fumes
probe.
All restore operations must be carried out by an authorised
technician.
HIGH TEMP
Overloading of pellets.
Adjust the  ow of pellets (see “Pellet Feed Adjustment”).
Other restore operations must be carried out by an
authorised technician.
DEPR FAIL
The door is not properly closed.
The ash drawer is not properly
closed.
The depression sensor is faulty.
The heating chamber is dirty.
The fume exhaust pipe is blocked.
Verify the hermetic closure of the door.
Verify the hermetic closure of the ash drawer.
Verify exhaust pipe and heating chamber are clean.
Other resetting operations must be carried out by an
authorised technician.
NO ACC
The pellet tank is empty.
Pellet load calibration inadequate.
Check the level in the pellet hopper.
Check the procedures described in Lighting”.
Adjust the  ow of pellets (see Pellet Feed Adjustment”)
Other restore operations must be carried out by an
authorised technician.
NO ACC
BLAC OUT
No electricity during the lighting
phase.
Place the stove in OFF using key 1 and repeat the procedures
described in the “Lighting” chapter.
Other restore operations must be carried out by an
authorised technician.
NO PELL
The pellet tank is empty.
No pellet load.
The geared motor does not load
pellets.
Check the level in the pellet hopper.
Adjust the  ow of pellets (see Pellet Feed Adjustment”).
Other restore operations must be carried out by an
authorised technician.
ATTE +
ALLARME
An attempt is made to reset an alarm
white the stove is still cooling.
Whenever one of the alarms described above is tripped, the
stove automatically shuts down.
During this phase, any attempt to reset the alarm will be
blocked, and the display will show the alarm and ATTE in
alternation.
Resetting the alarm by pressing button 1 is only possible after
the stove has completely shut down.