TABLE OF DISPLAY MESSAGES
Chapter 14
INDICATOR LIGHTS
LED indicator
Meaning Description
light
Weekly Programmer function.
It is switched on when the weekly programmer is active.
For all settings relating to the following function, see “Weekly
programmer” paragraph.
“Room Thermostat” function.
This LED is on/o when the room temperature is lower/higher
than the temperature set.
To modify the temperature setting, use buttons 2 and 3 during
normal operation.
“Day/Night Temperature” function.
It is switched on when “Day-night temperature function” is
active.
To enable/disenable the “Day/Night Temperature function”,
press button 4 and hold it down, then press button 5. For all
settings related to this function, see the section Day/Night
Temperature Function.
Spark plug disactivation.
This LED is on/o when the spark plug is active/inactive.
To reactivate the spark plug, contact an authorised
technician.
Exhaust motor operation.
It is switched on when fume exhaust motor is active.
If ashing contact an authorised technician.
Pellet feed motor operation.
It is switched on when the pellet loading motor is active.
During the normal functioning, the following light switches
on intermittently.
Blower operation. It is switched on when the tangential fan is active.
DIVINA PLUS model only -
Heat distribution motor operation.
It is switched on when the channelling motor is active.
If flashing, verify “Mechanical thermostat function for
commanding channelling motor” paragraph”.
DIVINA PLUS model only -
Status of supplementary thermostat.
Normally this LED is ALWAYS on.
When you connect an external thermostat to control the
distribution motor, this LED is on/o when the external contact
is open/closed.
Does not indicate any functioning. This light must be off at all times.
Communication established between
remote control and stove.
Each time you press a button on the remote control, this LED
should light up.
If it stays on, it means that communication between the
remote control and the stove is blocked.
To reset remote control operation, contact an authorised
technician.