Environmental component Specification
ERS 3626GTS - 41.2dB@25C, 49.3dB@50C
ERS 3626GTS-PWR+ - 44.6dB@25C, 54.5dB@50C
Miscellaneous Operating Considerations • At least 5cm (2") on each side of the switch unit for
ventilation
•
Adequate power source within six feet. One 15 amp
circuit required for each power supply
• No excessive dust
• No nearby sources of severe electromagnetic noise
• No nearby heat sources such as hot air vents or
direct sunlight
Power Specifications
This section provides the following specifications for
ERS 3600 Series.
Table 6: AC power specifications
Model Power supply Input power (margined by
10%)
Power consumption
(Thermal rating)
Rated Line
voltage
Watts
(T
otal)
Amps Watts BTUs/
hour
ERS 3626GTS 54W 100V-110V
AC
24.60 0.42 24.60 83.94
54W 200-240VA
C
24.78 0.24 24.78 84.55
ERS 3626GTS-PWR+ 914.1W 100V-110V
AC
874.92 7.05 151.90 518.35
54W 200-240VA
C
828.69 3.66 105.70 360.61
ERS 3650GTS 54W 100V-240V
AC
41.77 0.69 41.77 142.52
54W 200-240VA
C
41.54 0.41 41.54 141.73
ERS 3650GTS-PWR+ 914.1W 100V-240V
AC
903.51 8.21 163.91 559.26
914.1W 200-240VA
C
858.16 3.79 120.06 409.64