Environmental component Specification
ERS 3626GTS - 41.2dB@25C, 49.3dB@50C
ERS 3626GTS-PWR+ - 44.6dB@25C, 54.5dB@50C
Miscellaneous Operating Considerations At least 5cm (2") on each side of the switch unit for
ventilation
Adequate power source within six feet. One 15 amp
circuit required for each power supply
No excessive dust
No nearby sources of severe electromagnetic noise
No nearby heat sources such as hot air vents or
direct sunlight
Power Specifications
This section provides the following specifications for
ERS 3600 Series.
Table 6: AC power specifications
Model Power supply Input power (margined by
10%)
Power consumption
(Thermal rating)
Rated Line
voltage
Watts
(T
otal)
Amps Watts BTUs/
hour
ERS 3626GTS 54W 100V-110V
AC
24.60 0.42 24.60 83.94
54W 200-240VA
C
24.78 0.24 24.78 84.55
ERS 3626GTS-PWR+ 914.1W 100V-110V
AC
874.92 7.05 151.90 518.35
54W 200-240VA
C
828.69 3.66 105.70 360.61
ERS 3650GTS 54W 100V-240V
AC
41.77 0.69 41.77 142.52
54W 200-240VA
C
41.54 0.41 41.54 141.73
ERS 3650GTS-PWR+ 914.1W 100V-240V
AC
903.51 8.21 163.91 559.26
914.1W 200-240VA
C
858.16 3.79 120.06 409.64
Technical Specifications
February 2020 Installing Ethernet Routing Switch 3600 Series 17

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeSwitching 3600 Series and is the answer not in the manual?

Extreme Networks ExtremeSwitching 3600 Series Specifications

General IconGeneral
BrandExtreme Networks
ModelExtremeSwitching 3600 Series
CategorySwitch
LanguageEnglish

Related product manuals