DXP HD 4K PLUS Series • SIS Configuration and Control 40
Device-Initiated Messages
When a local event such as a front panel selection or adjustment takes place, the matrix
switcher responds by sending a message to the host. No response is required from the
host. Example switcher-initiated messages are listed here.
]
Password:
The ]Password: prompt requires a password (administrator level or user level)
followed by a carriage return. If the correct password is entered, the unit responds with
]Login Administrator] or ] Login User ], depending on the password
entered. If passwords are the same for both administrator and user, the switcher
defaults to administrator privileges.
The password prompt is redisplayed if an incorrect password is entered.
NOTES:
The factory configured passwords for all accounts on these devices have been
set to the device serial number. Passwords are case sensitive.
Performing a unit factory reset (entering an E ZQQQ
}
SIS command or
a mode 5 reset via the rear panel Reset button) removes the serial number
passwords, leaving the unit with no password.
Qik]
The switcher initiates the Qik message when a front panel switching operation occurs.
RprX1&]
The switcher initiates the Rpr message when a memory preset is recalled from the front
panel. X1& is the preset number.
SprX1&]
The switcher initiates the Spr message when a memory preset is saved from the front
panel. X1& is the preset number.
VmtX@*X1@]
The switcher initiates the Vmt message when a video output mute is toggled on or off
from the front panel. X@ is the output number. X1@ is the video mute status (0 = off,
1 = on).
AmtX@*X1#]
The switcher initiates the Amt message when an audio output mute is toggled on or off
from the front panel. X@ is the output number. X1# is the mute status (0 = off, 1 = on).
ExeX2)]
The switcher initiates the Exe message when the Front Panel Lockout mode is toggled
on or off from the front panel. X2) is the lock mode (0 = off, 1 = view only, 2 = basic
mode only)
HplgOX@ ]
The switcher initiates the HplgO message when a hot plug event is detected on an
output (for example, if the display is disconnected from the unit). X@ is the output
number.
Reconfig]
The switcher sends this response upon any change of input frequency on the currently
selected input or inputs.