EasyManua.ls Logo

Extron electronics ISM 824 - Command;Response Table for SIS Commands (Continued)

Extron electronics ISM 824
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-13
ISM 824 Integration Scaling Multiswitcher • SIS
Programming and Control
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Query firmware version Q/q
Q/q
Ver01*x.xx
]
View the rmware version.
View internal temperature 7S 7S
Sts7
X1@]
Internal temperature in
degrees Fahrenheit.
Digital sync validation
processing (DVSP)
X! LS X! LS X4*,X4*]
Listed as horizontal and
vertical frequencies.
View input video standard
38 *
X!# 21 %2A X! # Ist X!* X1!]
View setting.
With verbose 2/3 not activated
GGeneral information
I/i I/i
X\•X\•X\•X\
•X\•X\•X\•X\]
Query the configuration of all
outputs (listed 1-8).
Query part number N/n N/n 60-787-01]
View the part number (based
unit).
Query part number for slots *N/n *N/n
60-787-01.
X\
X\ X\ X\]
View the part number (slot
population from slot 1-4).
Where:
:X\ = Output (card) type
A = Universal scaler D =Dual-output wideband
B = Video-only scaler E = Scan converter
C = Single-output wideband
X = No output present
Z = Internal wideband output (outputs 1 and 2)
Query firmware version
Q/q Q/q
x.xxx
]
View the rmware version.
View internal temperature 7S 7S
Sts 7
X1(]
Internal temperature in degrees
Fahrenheit.
View input video standard
38 *
X!# 38 %2A X! # X1!]
View setting.
OOthers:
Front panel lockout (executive mode)
Enable lockout 1X 1X
Exe1
]
Lock front panel (admin).
Enable Admin lockout 2X 2X
Exe2
]
Lock front panel (complete).
Disable lockout 0X 0X
Exe0
]
Unlock front panel.
View lockout status X X
x!
]
Show executive mode status
x! = 0 (off), 1 (view only),
or 2 (I/O ties only).

Table of Contents