SW HD 4K PLUS Series • Installation 7
SW6 and SW8 — The CONTACT IN/TALLY OUT panel contains six (SW6) or eight
(SW8) 3-pole captive screw connectors, each with a C (contact), T (tally), and G
(ground) pin.
(Optional) Connect a push-button contact closure device to the C and G pins of
one of the 3-pole connectors (see figure3,
G
, on page 5). Connect an indicator
device, such as an LED, to tally output pin T of the same connector, to identify the
currently selected input when the front panel buttons are not visible.
See Wiring the CONTACT/TALLY Connectors on page10 for more information.
H
Reset button —The Reset button initiates three modes of reset for the switcher. For
the different reset levels, press and hold the button while the switcher is running or
while you power up the switcher (see Resetting on page16 for details).
NOTE: The factory configured passwords for all accounts on this device have been
set to the device serial number. In the event of an absolute system reset, the
passwords convert ot the default, which is no password.
Wiring the Power Connector (SW2 and SW4 HD 4K PLUS Only)
A 12 VDC, 1.5 A, pre-wired power supply is provided with the SW2 and SW4 HD 4K PLUS.
If, instead, you intend to use a different power supply, follow the instructions beginning on
the next page to wire the provided 2-pole captive screw connector to your power supply.
CAUTION: The wires must be kept separate while the power supply is plugged in.
Remove power before wiring.
ATTENTION : Les deux cordons d’alimentation doivent être tenus à l’écart l’un
de l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
ATTENTION:
Always use a power supply supplied and or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit
final.
If not provided with a power supply, this product is intended to be supplied by a
power source marked “Class 2” or “LPS” and rated at 12 VDC and a minimum of
1.5 A.
Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit
être alimenté par une source d’alimentation de classe 2 ou LPS et paramétré à 12
V et 1.5 A minimum.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical
Code, partie1, section16. La source d’alimentation ne devra pas être fixée de
façon permanente à une structure de bâtiment ou à une structure similaire.