SW HD 4K PLUS Series • Operation 17
Reset Mode Summary
Mode Activation Result Notes
Reset
System
Settings
Press and hold down the R button until
the all the front panel LEDs blink once
(at 3 seconds). Then, press R again
momentarily (for less than 1 second).
The unit returns to factory defaults except
for the firmware version and IP settings.
Use this mode to return
all system settings
to factory defaults
while retaining all IP
settings and the current
firmware version.
This is equivalent
to the
E
ZXXX
}
SIS command
(see Resetting on
page16).
Reset IP
and System
Settings
Press and hold down the R button until
all the front panel LEDs blink twice
(approximately 10 seconds). Then,
press R again momentarily (for less
than 1 second).
The device reverts to the factory defaults
except for the firmware version.
All system settings revert to the factory
defaults.
All user modifiable configurations are
reset to default values, including IP
settings (IP address, subnet mask,
gateway address, unit name, DHCP
setting, and port mapping) and real-time
adjustments.
All user loaded files are deleted.
NOTE: This reset also removes the
initial serial number passwords and
sets them to no password.
Use this mode to
reset all IP and system
settings to factory
defaults while retaining
the current firmware
version.
This is equivalent to the
SIS command ZQQQ
(see Absolute system
reset on page28).
Reset All
Settings
to Factory
Defaults
Using an Extron Tweeker or other
small screwdriver, press and hold in
the recessed R (Reset) button while
connecting power to the switcher.
The device reverts to the factory firmware,
IP, and system default settings.
The unit reverts to the factory-installed
firmware version.
All system settings revert to the factory
defaults.
All user modifiable configurations are
reset to default values, including IP
settings (IP address, subnet mask,
gateway address, unit name, DHCP
setting, and port mapping) and real-time
adjustments.
All user loaded files are deleted.
Use this mode to
restart with the default
configuration.
EDID Minder
EDID Minder ensures that a source device connected to the SW HD 4K PLUS input
continuously recognizes the EDID of a sink device, even if the sink is not physically
connected. By default, the EDID is set to 1080p @ 60 Hz with 2-channel audio.
EDID can be set to match output rate, a custom user-defined EDID, or a factory setting.
A variety of EDID are available to be loaded via PCS and assigned to the inputs (see
the SW HD 4K PLUS PCS Help file, provided with the PCS program, for information on
assigning EDID).