SW HD 4K PLUS Series • Remote Configuration and Control 28
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Verbose Mode
Set verbose mode
EX1@
CV
}
Vrb
X1@]
Set the verbose mode to
X1@
.
View verbose mode
E
CV
} X1@]
In verbose modes 2 and 3:
Vrb
X1@]
View current verbose mode
X1@
.
KEY:
X1@
= Verbose mode 0 = None (default for IP connection)
1 = Verbose mode (default for USB and RS-232 connections)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
See the Verbose mode symbol definition for details on these modes.
Resetting
Reset all device settings to
factory defaults
E
ZXXX
}
Zpx
]
Reset product-specific settings to
factory default values. Does not
affect IP settings or user files.
IP system reset
E
1ZQQQ
}
Zpq1
]
Reset only IP settings to factory
values.
Reset all settings except IP
settings
E
ZY
}
Zpy
]
Reset all device settings to
factory defaults except IP
settings (communication is
preserved). This command
is recommended for after a
firmware update.
Absolute system reset
E
ZQQQ
}
Zpq
]
Reset all device settings to
factory default except firmware
version.
NOTE: The factory configured passwords for all accounts on this device have been set to the device serial number. In the
event of an absolute system reset, the passwords convert ot the default, which is no password.
IP Configuration
NOTE: After adjusting any IP setting, enter the network reboot command
E
2BOOT
}
for the command to take effect.
Set date and time
24
EX1(
CT
}
Ipt
X2)]
Set date and time
X1(
in the
format MM/DD/YY-HH:MM:SS
(month/day/year-hour/
minutes/seconds)
Example: 06/22/17-10:07:14.
In this example, the date is
June 22, 2017, and the time is
10:07 and 14 seconds.
The unit responds with
X2)
.
NOTE: When power is cycled to the unit, the date and time are reset to the factory default values.
View date and time
E
CT
} X2)]
In verbose modes 2 and 3:
Ipt
X2)]
Show current date and time
X2)
in the format:
Ddd, DD Mmm YYYY HH:MM:SS
Set IP address
24
EX2!
CI
}
Ipi
X2!]
Set IP address
X2!
.
KEY:
X1(
= Local date and time (to set) Format MM/DD/YY-HH:MM:SS
X2)
= Local date and time (displayed) Format Ddd, DD Mmm YYYY HH:MM:SS
X2!
= IP address Format nnn.nnn.nnn.nnn

Related product manuals