3
B614 11 732998 - Rev.A_DRAFT
1
2
Translation of the original instructions
ENGLISH
B614 220-240 V ~ B614 115 V ~
Supply voltage 220-240 V~ 50/60 Hz 115V~ +/-10% 50/60 Hz
Electric motor 24 V
"
24 V
"
Max power 165 W 165 W
Max torque 300 Nm - 63 Nm (Breakaway - 45°) 300 Nm - 63 Nm (Breakaway - 45°)
Opening time (80°)
- beam 3 m
- beam 5 m
< 2 sec.
< 3 sec.
< 2 sec.
< 3 sec.
Use frequency 100 % 100 %
Ambient operating temperature -20 °C ... +55 °C -20 °C ... +55 °C
Ingress protection IP 55 IP 55
Dimensions (L x D x H) 247 x 357 x 1163 mm 247 x 357 x 1163 mm
Weight 40 kg 40 kg
Base plate FAAC
Dimensions (L x H) 230 x 305 mm
Beam FAAC Beam length
Rectangular beam 2.00 ... 4.85 m max
Round beam 2.00 ... 5.20 m max
6 Technical data
3.7 MANUAL OPERATION
!
- Performing the release manoeuvre when there is no
electrical power.
- Performing the release manoeuvre only when the beam
is at a standstill.
- During manual handling, accompany the beam slowly
for the entire stroke. Do not let the beam travel freely.
- Do not leave the barrier unblocked: after carrying out
the manual movement, restore automatic operation.
RELEASE PROCEDURE
1. 3 Open the lock cover. Insert the key and turn
it once anticlockwise until it stops (1).
2. Move the automation manually.
3. Restore the operation
OPERATION RESTORATION
1. 3 Insert the key and turn it twice clockwise
until it stops (2).
2. Check that manual movement is inhibited.
3. Remove the key and close the cover