B614 32 732998 - Rev.A_DRAFT
Translation of the original instructions
ENGLISH
7. ELECTRONIC INSTALLATION
RISKS
PERSONAL PROTECTIVE EQUIPMENT
F
ALWAYS DISCONNECT THE POWER SUPPLY before working
on the board. Turn power on only after having made all
the electrical connections and carried out the preliminary
start-up checks.
The board cover must never be removed unless the board
is to be replaced. No installation operation requires the
removal of the cover.
7.1 BOARD E614
7 Board technical data sheet E614
230V~ 115V~
Supply voltage 220-240 V~ 50/60 Hz 115V~ +/-10% 50/60 Hz
Max power 150 W 150 W
Accessory output voltage 24 V
"
24 V
"
Max. accessories load 500 mA 500 mA
Max. accessories load BUS 2easy 500 mA 500 mA
Max. flashing light load
Ambient operating temperature -20 °C - +55 °C
COMPONENTS
See figure 42
BOARD:
J1 Mains power supply terminal board
J3 Terminal board for BUS 2easy
J6 Accessory/input terminal board
J7 Radio module connector XF
J8 Battery connector XBAT 24
J10 Terminal board for external detector LOOP1
J11 Connector for encoder
J13 Terminal board for external detector LOOP2
J16 Terminal board for external flashing light
J18 Terminal board for the beam lights
J20 Terminal board for outputs
J21 Connector for integrated flasher
J23 Connector for motor
F3 Board protection fuse (F3 = T2.5A)
DISPLAY Programming display
BOARD:
DL1 Device signalling LED to BUS 2easy ACTIVE
DL2 BUS 2easy “BUS MON“ diagnostic signalling LED
DL3 “RADIO1” (OMNIDEC) signalling LED
DL4 “RADIO2” (OMNIDEC) signalling LED
DL5 Error/alarm signalling LED
DL8 EMER status LED
DL9 STOP/FSW-CL status LED
DL10 CLOSE status LED
DL11 OPEN status LED
DL12 LOOP1 status LED
DL13 LOOP2 status LED