B614 52 732998 - Rev.A_DRAFT
Translation of the original instructions
ENGLISH
SLAVE BARRIER CONFIGURATION
1. Power Slave barrier The board turns on. The
display reads in sequence:
- firmware version (2 digits separated by a dot)
- SO flashing if a set-up or the automation status is
requested
2. Access the Basic programming and set:
-
cF depending on the beam configuration and
length
- Ct=SL for configuring the board as Slave.
3. Check the status of the LEDs on the board:
LED DL7 (Red)
Master-Slave synchronisation absent or the line
is short circuited.
LED DL3 (Green)
Master-Slave synchronisation present.
4. Check the direction of travel (see § 12.2). The
barrier must not be in manual functioning mode.
5. Start up (see § 8).
During the set-up the Master board controls the Slave
board and the two beams move with a synchronous
movement.