Basic function Default
Sc
CLOSURE SPEED
01 minimum speed
10 maximum speed
See tab.
Speed de-
fault
bu
DEVICE REGISTRATION BUS 2easy
See the relative section.
no
M1
Dead-man MOTOR OPERATION mode
+
OPENS (displaying oP) as long as the button
remains pressed.
-
CLOSES (displaying cL) as long as the but-
ton remains pressed.
--
tL
SET-UP
Acquire the limit switch positions.
See the relative section.
no
St
LEAVING THE PROGRAMMING MODE
Y save and exit from programming mode
no exit from programming mode without
saving
Press F to confirm. After exiting, the display
indicates the status of the automation system:
00 = Closed
01 = Open
02 = Stationary then opens
03 = Stationary then closes
04 = Pausing
05 = Opening
06 = Closing
07 = Failsafe underway
08 = Check of BUS 2easy device underway
09 = Pre-flashing and then opens
10 = Pre-flashing and then closes
11 = Opening in emergency
Y
10 Advanced programming
Advanced function Default
PF
PRE-FLASHING
no disabled
OC preflashing 3 sec. before each movement
no
FO
DRIVING FORCE ON OPENING
01 minimum power
50 maximum power
50
FC
DRIVING FORCE ON CLOSURE
01 minimum power
50 maximum power
50
SP
STOP INPUT CONFIGURATION
It defines the function of the STOP input
00 (STOP) Stop
02 (FSW-CL) Closure photoelectric cell
00
t
OPERATING TIME (time-out)
Set a higher value than the time the barrier needs
to open/close completely.
This can be regulated from 0 to 59 secs. in 1 sec
steps. Afterwards, the display changes in minutes
and tens of seconds (separated by a dot) and the
time is regulated in 10 sec. steps, up to a maximum
value of 9.5 minutes.
E.g.: if the display indicates
2.5, the pause time is
2 min and 50 sec.
In the case of a plant with a Master/
Slave configuration an operating time
must be set on the Master central
control unit that takes account of the
movement of both the barriers.
5.0
o1
OUT OUTPUT 1 CONFIGURATION
00 Always active
01 failsafe
02 telltale light (on during opening/pause/
open, flashing on closure, off when closed)
03 courtesy light
05 barrier open or in pause mode
06 barrier closed
07 barrier moving
08 barrier in emergency mode
09 barrier opening
10 barrier closing
12 safety device active
13 light column (active in pause mode/open,
turns off on closure)
15 step by step activation through second radio
channel
19 battery operation
20 Loop1 engaged
21 Loop2 engaged
00
9 Speed default
cF 01 cF 02 cF 03
So
10 06 02
Sc
08 04 02