Basic function DEFAULT
SP
SPEED Speed of movement.
01… 10 (levels)
08
En
ENCODER Enables/disables the encoder on both motors.
no disabled, Y enabled
Y (non-modifiable) if cF=03 or 05 or 06 or 07
no
if cF=00 or 01 or 02 or 04
no
(non-modifiable) if cF=08
FA
OPENING LIMIT SWITCH Enables/disables the opening limit
switches, to stop the automation or start the slowdown. Modi-
fying the value requires a new SETUP.
no disabled, 01 to stop, 02 to start slowdown
no
FC
CLOSING LIMIT SWITCH Enables/disables the closing limit
switches, to stop the automation or start the slowdown. Modi-
fying the value requires a new SETUP.
no disabled, 01 to stop, 02 to start slowdown
no
Cd
CLOSING DELAY NOT displayed if Mn = 1 . The delay is
applied to Leaf 1.
00… 59 s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds
(separated by a point), up to a maximum of
1.3 minutes.
1.0…1.3 Adjustment step: 10 s
E.g.
1.2 = 1 min and 20 s.
05
bu
BUS 2easy REGISTRATION See the § specific section.
no
M2
MOTOR 2 OPERATION NOT displayed if Mn = 1. In this
function, buttons + and - operate Motor 2 in hold-to-run mode.
++ OPEN (displaying oP),
--
CLOSE (displaying cL)
--
M1
MOTOR 1 OPERATION In this function, buttons + and - oper-
ate Motor 1 in hold-to-run mode.
++ OPEN (displaying oP),
--
CLOSE (displaying cL)
--
tL
SETUP See the § specific section.
--
St
LEAVING THE PROGRAMMING MODE
Y Exit saving the settings
no Exit without saving the programming
After having confirmed using button
FF, the display indicates the
STATUS of the automation:
Y
00 CLOSED
01 OPEN
02 STATIONARY THEN OPENS
03 STATIONARY THEN CLOSES
04 in PAUSE
05 OPENING
06 CLOSING
07 FAIL- SAFE in progress
08 VERIFYING BUS 2easy
09 PRE-FLASHING and then OPENS
10 PRE-FLASHING and then CLOSES
11 EMERGENCY OPEN
12 EMERGENCY CLOSE
HP Hold Position
. (point flashing) SLEEP