2 Basic programming menu
Basic function DEFAULT
][
Simply Connect To enable Simply Connect, select a com-
munication channel (CH 1…4).
0 disabled, 1 (CH 1), 2 (CH 2), 3 (CH 3), 4 (CH 4)
0
cF
TYPE OF AUTOMATION Select the type of actuator installed
(board loads the relative default configuration).
0
The letters EP indicate a "mixed" automation: 2 leaves with 2
different actuators (from Simply Connect).
00 no FAAC actuator
01 412, 413, 415, 770, 390, 770N
02 391
03 S700H/S800H
04 S418
05 S450H
06 S800H ENC
07 S2500 I
08 S800H without
encoder
dF
DEFAULT CONFIGURATION Y indicates if the programming
corresponds to the default settings. Select
Y if you wish to
reload the default values for the type of automation.
Y the programming corresponds to the DEFAULT settings
no the programming does not correspond to the DEFAULT
settings
Y
LO
OPERATING LOGICS
E
E Semi-automatic
EP Semi-automatic step by
step
S Automatic Safety
SA Automatic Safety 2
SP Automatic step by step
A1 Automatic 1
A Automatic
AP Automatic step by step
At Automatic with timer
function
b Semi-automatic b
bC Mixed (Impulse open-
ing / Hold-to-run closing)
C Hold-to-run
CU Displayed if there
is a CUSTOM logic from
Simply Connect.
PA
PAUSE TIME A Displayed only in logics with automatic clos-
ing. This function specifies the pause time if the automation
has been opened by the OPEN A command.
0059 s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds
(separated by a point) and the time is adjusted in 10 s steps, up
to the maximum value of
9.5 minutes.
E.g.
1.2 = 1 min and 20 s
30
Pb
PAUSE TIME B Displayed only in logics with automatic clos-
ing. This function specifies the pause time if the automation
has been opened by the OPEN B command (adjustment similar
to
PA)
30
Mn
NUMBER of MOTORS enabled.
1 1 motor, 2 2 motors
2
F1
MOTOR 1 POWER
0150 (levels)
25 if cF=00 or 01 or 02 or 04
40
if cF=03 or 06 or 08
35
if cF=05
15
if cF=07
F2
MOTOR 2 POWER NOT displayed if Mn = 1.
0150 (levels)
25 if cF=00 or 01 or 02 or 04
40
if cF=03 or 06 or 08
35
if cF=05
15
if cF=07