19
E124S 33 532434 - Rev.A
-
+
-
RADIO / DECODER
CLOCK BATTERY
BATTERY
RESET
SETUP
R2
R1
PRGRM
LCD1
POWER
SUPPLY
F
RADIO +
+
8.8.
1 2 1 2 1 23 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20
DL1
DL2 DL3 DL4 DL9 DL10 DL11DL12
SW3
DL14
BATTERY
SW1
SW2
DL13 DL5 DL6 DL7 DL8
ALARM
RESET
DL12 DL1 DL2 DL3 DL4 DL6 DL7 DL8 DL9DL5DL13 DL10 DL11
2EASY OUT2 OUT1
LAMP
LOCK MOT1 MOT2
+
-
+
-
IN1
IN2
IN4
IN5
GND
IN3
GND
+24
FCA1
FCC1
FCC2
FCA2
GND
GND
GND
ENC1
+24
ENC2
LED MAIN
LED ALARM
LED RESET
LED R1
LED R2
LED SETUP
LED BATTERY
LEDs IN
LEDs
2EASY
LEDs FC LEDs ENC
Translation of the original instructions
ENGLISH
IN1
(DL1)
OPEN A command
active
not active
IN2
(DL2)
OPEN B command
active
not active
IN3
(DL3)
STOP command
not active
active
IN4
(DL4)
Opening protection
command
photocells not en-
gaged
photocells engaged
IN5
(DL5)
Closing protection com-
mand
photocells not en-
gaged
photocells engaged
FCA1
(DL6)
Opening limit switch
not engaged
engaged
FCC1
(DL7)
Closing limit switch
not engaged
engaged
FCA2
(DL8)
Opening limit switch
not engaged
engaged
FCC2
(DL9)
Closing limit switch
not engaged
engaged
ENC1
(DL10)
Gatecoder Leaf1
moving
ENC2
(DL11)
Gatecoder Leaf2
moving
2EASY
RED
(DL12)
BUS 2easy operation
(detectors or pulse gen-
erators in operation)
At least one device in op-
eration
NO devices in operation
2EASY
GREEN
(DL 13)
BUS 2easy diagnostics
OK (normal operation)
SLEEPING
SHORT CIRCUIT
ERROR
MAIN
(DL14)
Mains power supply
on
off
BATTERY Secondary power supply
battery charged
battery discharged
battery operation, or bat-
tery is charging
R1 Radio Channel 1
in learning mode
idle
R2 Radio Channel 2
in learning mode
idle
SETUP
(DL18)
SETUP phases
in progress
not running
RESET RESET
in progress
not running
ALARM Errors, Warnings
error in progress
warning in progress
no warnings
13. DIAGNOSTICS
SIGNALLING LEDS ON THE BOARD
condition with the board powered, the gate at the halfway position and no connected devices active.