NEW FEATURES
(SOFT M: 9.0X)
1.2 Modified variables
HARCON It indicates, with bits, the CNC's hardware configuration. The bit will
be "1" when the relevant configuration is available.
8055 CNC model:
8055i CNC model:
HDMEGA Hard disk size in megabytes.
MEMTST HD test result. Bit 8 will be set to "1" if the test is OK and it will have
another value if there is an error.
1.3 Modified programming instructions
"OPEN" instruction.
When programming the OPEN instruction, the target directory is
selected as follows:
Bit Hardware
29 Hard disk integrated into the CPU.
30 Ethernet integrated into the CPU.
31 Compact flash.
Bit Hardware
30 Ethernet.
31 Compact flash.
CARDA in the "Memkey Card".
HD in the Hard Disk.
DNC1 in a PC connected through serial line 1.
DNC2 in a PC connected through serial line 2.
DNCE in a PC connected through Ethernet.