EasyManua.ls Logo

Fagor DDS - Page 323

Fagor DDS
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functional safety
FUNCTIONAL SAFETY
Commissioning
9.
323
DDS
HARDWARE
Ref.1310
9.9 Commissioning
Check that each of the two channels of the STO, i.e. - KM1 and Drive En-
able, separately, remove motor torque.
Also check the feedback of each channel.
Document the tests of the safety function on the minutes (record).

Other manuals for Fagor DDS

Related product manuals