10.
F. H1 0/1 3
F. H1 0/1 4
Note. CNC EMERG. will always be assigned to I1/O1 of the PLC with an 8055/55i CNC. With an
8070 CNC, it may be assigned to any I/O of the PLC. The contacts associated with relays - KA2, -
KA3, - KA4, - KA5, - KA6 and - KA7 are shown inside a circle in figure
F. H10/12 and the contactor -
KM1 in figure
F. H10/14.
Note. The relay - KA3 uses delayed
deactivation (t seconds) maintaining
the DRIVE ENABLE control signal
active for a few seconds to maintain
motor torque while the vertical axis
holding brake is enabled.
See parameter GP9 in the
“man_dds_soft.pdf” manual.
OPERATION DIAGRAM. PS-25B4
PE
- S1
MECHANICAL
MAIN SWITCH
- F3
- F4
- F5
MAINS FILTER 42A
L1
L3
L2L1
3x400-460 VAC
2x400-460 VAC
R
S
T
R
S
T
CONTACTOR
- KM1
L2
N
- Q1
DIFFERENTIAL
BREAKER
WARNING. When using an isolating transformer, the secondary must be
connected in star and its middle point must be connected to GND.
POWER MAINS
IT A MUST TO USE FUSES
TO THE POWER CONNECTOR
PS-25B4 POWER SUPPLY
TO THE X3 CONNECTOR
PS-25B4 POWER SUPPLY
Note. Observe that having the main key - S1 closed, although
the power contactor - KM1 is open, the internal auxiliary
power supply remains connected through its connector X3 to
feed the control circuits of the drive.
GENERAL DIAGRAM. PS-25B4