Drive modules
DRIVE MODULES
Modular drives
3.
99
DDS
HARDWARE
Ref.1310
T. H3 /5 Technical characteristics of the modular drives.
AXD/SPD/MMC
1.08 1.15 1.25 1.35 2.50 2.75 2.85 3.100
3.150
3.200
3.250
Power voltage input 542 - 800 V DC
Power to control circuits 24 V DC (between 21 V DC and 28 V DC)
Consumption of the control
circuits (24 V DC)
0.90 A 1.25 A 2.00 A
Speed feedback Encoder
Controlling method PWM, AC sinewave, vector control
Communication Serial line to connect to a PC
Interface
Standard analog, digital SERCOS ring (in all models)
CAN bus (in all models).
Serial line RS-232/422 (only in MMC drives)
Status display 7-segments display
Protections
Over-voltage, over-current, over-speed, heat-sink temperature,
ambient temperature, motor temperature, hardware error, overload.
Speed range with analog input 1:8192
Current bandwidth 800 Hz
Speed bandwidth 100 Hz (depends on the motor/drive set)
Ambient temperature
Between 5 °C and 45 °C (41 °F/113 °F)
From 40 ºC (104 ºF) on. See derating curves.
Storage temperature Between - 20 °C and + 60 °C (- 4 °F/140 °F)
Sealing IP 20
Maximum humidity < 90% (non condensing at 45 °C/113 °F)
Operating vibration 0.5 G
Shipping vibration 2 G
Approx. mass in kg
lb
5.5
(12.1)
6.0
(13.2)
6.5
(14.3)
9.0
(19.8)
9.0
(19.8)
10.0
(22.0)
14.0
(30.8)
19.5
(43.0)