Problem Possible cause Remedy
A servo
does not
work.
The Servo Control is
not connected to the
supply voltage.
X
Connect 16 V alternating
voltage to the »16 VAC«
port of the Servo Control.
Polarity of the connec-
tor of the servo has
been reversed.
X
Rotate the plug of the servo
by 180°.
The rock-
ing func-
tion does
not work.
The configuration var-
iable of the ampli-
tude of oscillation has
be given the value 0
or 127 (minimum and
maximum values). This
makes the servo una-
ble to carry out the
rocking motion.
X
Give a value that is higher
than 0 and lower than 127.