TST Expanded Startup WU
FEIG ELECTRONIC GmbH Page 7 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc
6 Maintenance counter
The door controller has a maintenance counter.
Parameter P.005 is used to show the possible open and close cycles until maintenance is due.
Setting Parameter P.973 to 1 resets the maintenance counter.
There are various ways for the maintenance notification to be displayed to the user:
After the maintenance counter has expired
1: Warning I.080 is displayed
2: Only automatic opening and deadman closing are possible and error F.080 is output.
3: Only deadman travel is possible and error F.080 is output
This setting is made at the factory and cannot be changed here.