FERROLI F30
2
0
Fig. 21h
Fix with the screws (b). Refi t wiring connections to fan and air pressure switch tubes ensuring correct
orientation. I.E. red tube to air pressure switch connection with red dot (+) and clear tube to air pressure
switch connection with no paint marking (-).
Fit the fan into the boiler rotating the front to engage with the pin a. Secure with the screws b.
Rear
b
b
Back fl ue outlet (Diagram 1-9)
Fig. 22a
Fig. 22b Fig. 22c
1. Core drill 127mm hole (5").
2. Push through the outer ue. 3. Gently pull back until wall seal
is ush with the wall.
6. Cut the outer ue ush with the
ange on the hanging plate.
80 mm
7. Insert the aluminium ue pipe
into white plast ic outer flue,
making sure the aluminium pipe
sits fully and centrally into the
ue terminal. Mark the aluminium
ue pipe at the point it is ush
with the mounting plate. Add
36mm to this mark and cut the
aluminium inner flue pipe at
this point.
Fig. 22g
36 mm
80 mm
Fig. 22f