ferrotec CARRERA - Function Test Plan

ferrotec CARRERA
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 1.3_15 EN
49
High Voltage Power Supply
Type: CARRERA
8.3.1 Function test plan
Interval for One-Shift System
W
M
½ Y
Y
MIH
Emergency stop system (emergency stop buttons)
X
Mains isolator (main switch)
X
Check all electric terminal and plug connections
X
Push buttons and switches on the switch cabinet
X
Check all plug, screw and clamped joints for firmness
and tighten if necessary
X
Function check of the electric drives
X
8.3.2 Inspections
1. Carry out a visual inspection of the switch cabinet.
Check:
- the wiring for kinks, abrasions and burns,
- the covers and insulation for damage,
- the switch cabinet doors for ease of movement.
2. Carry out a function test of all subassemblies in setting mode
and in manual mode.
If all the functions work properly, the machine is handed over to
the operating personnel.