CMMP-AS-...-M0
6 Festo – GDCP-CMMP-M0-HW-EN – 1511c – English
Instructions on this documentation
This documentation is intended to help you safely work with the motor controller CMMP-AS-...-M0 and
describes the mounting and installation processes.
Target group
This documentation is intended exclusively for technicians trained in control and automation techno
logy, who have experience in installation, commissioning, programming and diagnostics of positioning
systems.
Product identification, versions
This description refers to the following versions:
– CMMP-AS-...-M0 from Rev 01
– FCT plug-in CMMP-AS from Version 2.3.x.
Note
Before using a newer firmware version, check whether a newer version of the FCT plug-
in or user documentation is available for it
Support Portal: è www.festo.com/sp
Rating plate (example) Meaning
In: 1* (100...230)V AC±10%
(50...60)Hz 3A
Out: 3*(0...270)V AC
(0...1000)Hz 2,5A
Max surround air temp 40°C
D-73734 Esslingen IP10/20
CMMP-AS-C2-3A-M0
1622901
XX Rev XX
IND. CONT. EQ.
1UD1
Type designation CMMP-AS-C2-3A-M0
Part number 1622901
Serial number XX
Revision status Rev XX
Input data 100 … 230 V AC ±10%
50 … 60 Hz 3 A
Output data
Degree of protection
0 … 270 V AC
0 … 1000 Hz 2.5 A
IP10/20
Max. ambient temperature 40 °C
Tab. 1 Rating plate example CMMP-AS-C2-3A-M0
Service
Please consult your regional Festo contact if you have any technical problems.
Specified standards/directives
Issue status
2006/42/EC EN 60204-1:2006-06/A1:2009-02
2006/95/EC EN 50178:1997-10
2004/108/EC IEC 61131-2:2007-09
EN 61800-3:2004-12 + A1:2012-3
Tab. 2 Standards/directives specified in the document