EasyManuals Logo

FIBARO ROLLER SHUTTER 3 User Manual

FIBARO ROLLER SHUTTER 3
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
28
ADVANCED PARAMETERS
60. Measuring power consumed by the device itself
This parameter determines whether the power metering should in-
clude the amount of active power consumed by the device itself.
Available settings: 0 - function inactive
1 - function active
Default setting: 0 Parameter size: 1 [byte]
61. Power reports - on change
This parameter determines the minimum change in consumed power
that will result in sending new power report to the main controller.
For loads under 50W, the parameter is not relevant and reports are
sent every 5W change.
Power report are sent no often then every 30 seconds.
Available settings: 0 - reports are disabled
1-500 (1-500%) - change in power
Default setting: 15 (15%) Parameter size: 2 [bytes]
62. Power reports - periodic
This parameter determines in what time intervals the periodic power
reports are sent to the main controller
. Periodic reports do not de-
pend on power change (parameter 61).
Available settings: 0 - periodic reports are disabled
30-32400 (30-32400s) - report interval
Default setting: 3600 (1h) Parameter size: 2 [bytes]
65. Energy reports - on change
This parameter determines the minimum change in consumed ener-
gy that will result in sending new energy report to the main controller.
Available settings: 0 - reports are disabled
1-500 (0.01 - 5 kWh) - change in energy
Default setting: 10
(0.1 kWh)
Parameter size: 2 [bytes]
66. Energy reports - periodic
This parameter determines in what time intervals the periodic energy
reports are sent to the main controller
. Periodic reports do not de-
pend on energy change (parameter 65).
Available settings: 0 - periodic reports are disabled
30-32400 (30-32400s) - report interval
Default setting: 3600 (1h) Parameter size: 2 [bytes]
POWER AND ENERGY REPORTING CONFIGURATION

Other manuals for FIBARO ROLLER SHUTTER 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO ROLLER SHUTTER 3 and is the answer not in the manual?

FIBARO ROLLER SHUTTER 3 Specifications

General IconGeneral
Device TypeRoller Shutter Controller
ProtocolZ-Wave
Radio ProtocolZ-Wave
Dimensions42.5 x 38.25 x 20.3 mm
Mounting Box RequirementsØ ≥ 50mm, depth ≥ 60mm
Protection ClassIP20
Maximum Load for AC Output4.2A
Max Transmit Powerup to 6 dBm
RangeUp to 50m (open space)
Operating Temperature0°C to 40°C
Z-Wave Frequency868.4 MHz EU
CompatibilityWorks with various Z-Wave and Z-Wave Plus certified devices
Radio Frequency868.4 or 908.4 or 921.4 MHz EU frequency band